GAS FLOW SYSTEM
The higher temperature Isotech Blackbody Fixed Point Cells consist of high purity metals within a graphite body. Graphite reacts with air to form Carbon Dioxide. The rate of the reaction is temperature dependant. The effect is small at low temperatures but increases at higher temperatures.
For Indium and Tin cells the effect is small and for Indium, Tin and Zinc cells in general no attention needs to be made. Yet for Aluminium, Silver and Copper Cells the oxygen must be excluded or the cells would be quickly damaged.
The Model 984 Gas Flow System connects between an inert gas supply, such as Argon or Nitrogen and the Cell in its apparatus. The Model 984 has a regulator and a flow meter optimised to easily set the flow to 0.2 L/min and features an audible alarm should the gas flow be interrupted.
- SPECIFICATION
| Model | 984 |
| Input-Output Connectors | Genevac 16KF |
| Alarm | Audible |
| Power | 15 Watts |
| Voltage | 12Vdc |
| Dimensions | Height 240mm Width 120mm Depth 220mm (excluding connection pipes) |
| Weight | 2.5kg |
| How to order | Model 984 Gas Flow System: Supplied with external power supply, 2 x connecting pipes and fittings. |


문의 010 7574 9841
평일 오전9시 ~ 오후6시 입니다. (공휴일은 통화불가합니다)
부재중일시 전화나 카톡 남겨주시면 업무시간때 체크후 피드백 드리겠습니다.
아이소텍 ・ ISOTECH
984
GAS FLOW SYSTEM
The higher temperature Isotech Blackbody Fixed Point Cells consist of high purity metals within a graphite body. Graphite reacts with air to form Carbon Dioxide. The rate of the reaction is temperature dependant. The effect is small at low temperatures but increases at higher temperatures.
For Indium and Tin cells the effect is small and for Indium, Tin and Zinc cells in general no attention needs to be made. Yet for Aluminium, Silver and Copper Cells the oxygen must be excluded or the cells would be quickly damaged.
The Model 984 Gas Flow System connects between an inert gas supply, such as Argon or Nitrogen and the Cell in its apparatus. The Model 984 has a regulator and a flow meter optimised to easily set the flow to 0.2 L/min and features an audible alarm should the gas flow be interrupted.
- SPECIFICATION
| Model | 984 |
| Input-Output Connectors | Genevac 16KF |
| Alarm | Audible |
| Power | 15 Watts |
| Voltage | 12Vdc |
| Dimensions | Height 240mm Width 120mm Depth 220mm (excluding connection pipes) |
| Weight | 2.5kg |
| How to order | Model 984 Gas Flow System: Supplied with external power supply, 2 x connecting pipes and fittings. |